Chapter 4 Removal and Replacement Procedures
Removing and Installing the Power Entry Modules (PEMs)
Figure 4-41 Catalyst 6503 Switch—Power Supply Location
Required Tools
Use a flat-blade or number 2 Phillips-head screwdriver to perform these procedures. Additionally, wire
cutters may be necessary to cut cable tie-wraps.
cutters may be necessary to cut cable tie-wraps.
Removing the AC-Input PEM
Follow these steps to remove an AC-input PEM:
Step 1
Turn the power switch to the Off (0) position on the PEM that you are removing. (See
Step 2
Disconnect the power cord from the power source. Do not touch the metal prongs on the power cord
when it is still connected to the PEM.
when it is still connected to the PEM.
Step 3
Remove the power cord from the power connection on the PEM. Do not touch the metal prongs
embedded in the PEM.
embedded in the PEM.
Step 4
Loosen the captive installation screws. (See
Step 5
Grasp the PEM with one hand, and slide it part of the way out of the chassis. Place your other hand
underneath the PEM, as shown in
underneath the PEM, as shown in
, and slide it completely out of the chassis.
Step 6
If the PEM bay is to remain empty, install a blank PEM filler plate (Cisco part number 800-16719-01)
over the opening, and secure it with the captive installation screws.
over the opening, and secure it with the captive installation screws.
63031
INPUT
OK
FAN
OK
OK
OUTPUT
FAIL
INPUT
OK
FAN
OK
OK
OUTPUT
FAIL
Power supply 2
(redundant)
Power supply 1