Cisco CATALYST 6509E 9 SLOT 15U CHASSIS NO POWER SUPPLY NO FAN TRAY Specification Guide

Page of 336
4-66
Catalyst 6500 Series Switches Installation Guide
OL-5781-04
Chapter 4      Removal and Replacement Procedures
  Installing the Air Filter Assembly on a Catalyst 6509-NEB-A Switch (Optional)
Installing the Air Filter Assembly on a Catalyst 6509-NEB-A 
Switch (Optional)
This section describes how to install the optional air filter assembly for the Catalyst 6509-NEB-A 
switch. The filter assembly is not included with the chassis or bundle configurations. The necessary parts 
can be ordered as listed in 
. The filter assembly installation requires that INTAKEPNL-09= be 
installed on the chassis. This intake panel can be identified by the two filter assembly support loops 
extending from the bottom front of the panel and the thumbscrews on the front left and right sides of the 
panel. (See 
Table 4-3
Air Filter Part Numbers
Perform these steps to install the new filter assembly. If INTAKEPNL-09= is already installed, skip to 
Step 3
.
Step 1
Remove the intake panel by unscrewing four thumbscrews. (See 
Figure 4-57 Removing the Intake Panel
Step 2
Install the new intake panel by tightening four thumbscrews. (See 
.)
Part Number
Description
INTAKEPNL-09=
Replacement Intake Panel
FLTRASSM-09=
Filter Cage Assembly, no filter inserts included
FLTRINSERTS-09=
Set of five replacement air filter inserts for 
FLTRASSM-09=
101391