Cisco CATALYST 6509E 9 SLOT 15U CHASSIS NO POWER SUPPLY NO FAN TRAY Specification Guide

Page of 336
D-4
Catalyst 6500 Series Switches Installation Guide
OL-5781-04
Appendix D      Chassis and Module Power and Heat Values
  
For all WS-X67xx modules, the values shown in 
 are for the baseboard only. When the 
baseboard has a CFC or DFC3 daughter card installed, you must add the daughter card power to the 
baseboard power to get the total slot power. For all other modules that support a mandatory or optional 
daughter card, you must add the daughter card power to the baseboard power to get the total slot power.
WS-SUP720-3BXL
Supervisor Engine 720 with 
PFC3BXL daughter card and 
integrated MSFC3 and switch 
fabric
7.82
328.44
410.55
1402.03
441.45
1507.56
WS-F6K-PFC3A
Policy Feature Card 3A
2.25
94.50
118.13
403.40
127.02
433.76
WS-F6K-PFC3B
Policy Feature Card 3B
2.25
94.50
118.13
403.40
127.02
433.76
WS-F6K-PFC3BXL
Policy Feature Card 3BXL
2.57
107.94
134.93
460.77
145.08
495.45
Table D-3
Power Requirements and Heat Dissipation—Supervisor Engines (continued)
Table D-4
Power Requirements and Heat Dissipation—Modules
Model Number/
Module Type
Module 
Current (A) 
@ 42 VDC
Module 
Power 
(Watts)
AC
DC
AC-Input
Power 
(Watts)
Heat Diss.
(BTU/HR)
DC-Input
Power 
(Watts)
Heat Diss.
(BTU/HR)
WS-F6K-DFC
Distributed Forwarding Card
2.10
88.20
110.25
376.50
118.55
404.84
WS-F6K-DFC3A
Distributed Forwarding Card 3A
2.57
107.94
134.93
460.77
145.08
495.45
WS-F6K-DFC3B
Distributed Forwarding Card 3B
1.67
70.14
87.68
299.41
94.27
321.95
WS-F6K-DFC3BXL
Distributed Forwarding 
Card 3BXL
2.38
99.96
124.95
426.70
134.35
458.82
WS-F6700-CFC
Centralized Forwarding Card
0.75
31.5
39.38
134.47
42.34
144.59
WS-F6700-DFC3A
Distributed Forwarding Card 3A
3.0
126
157.5
537.86
169.35
578.35
WS-F6700-DFC3B
Distributed Forwarding Card 3B
2.7
113.40
141.75
484.08
152.42
520.51
WS-F6700-DFC3BXL
Distributed Forwarding 
Card 3BXL
3.3
138.60
173.25
591.65
186.29
636.18