Cisco CATALYST 6509E 9 SLOT 15U CHASSIS NO POWER SUPPLY NO FAN TRAY Specification Guide

Page of 336
E-6
Catalyst 6500 Series Switches Installation Guide
OL-5781-04
Appendix E      Troubleshooting
  Troubleshooting Modules
Refer to the Catalyst 6500 Series Switch Software Configuration Guide, the Catalyst 6500 Series Switch 
Cisco IOS Software Configuration Guide
, the Catalyst 6500 Series Switch Command Reference, or the 
Catalyst 6500 Series Switch Cisco IOS Command Reference publications to configure or enable the 
interfaces. After the system reinitializes the interfaces, the status LED on the module should be green.
If you still experience trouble with the startup, see the 
Table E-1
Environmental Monitoring for Supervisor Engine and Switching Modules
Component
Alarm 
Type
LED Indication
Action
Supervisor engine temperature sensor 
exceeds major threshold
1
 
1.
Temperature sensors monitor key supervisor engine components including daughter cards.
Major STATUS
2
 LED red
3
 
2.
A STATUS LED is located on the supervisor engine front panel and all module front panels.
3.
The STATUS LED is red on the failed supervisor engine. If there is no redundant supervisor, the SYSTEM LED is red also.
Syslog message and SNMP trap generated.
If redundancy, system switches to redundant 
supervisor engine and the active supervisor engine 
shuts down.
If there is no redundancy and the overtemperature 
condition is not corrected, the system shuts down 
after 5 minutes.
Supervisor engine temperature sensor 
exceeds minor threshold 
Minor
STATUS LED 
orange 
Syslog message and SNMP trap generated.
Monitor the condition.
Redundant supervisor engine 
temperature sensor exceeds major or 
minor threshold 
Major
Minor
STATUS LED red
STATUS LED 
orange
Syslog message and SNMP trap generated.
If major alarm and the overtemperature condition is 
not corrected, the system shuts down after 5 minutes.
If minor alarm, monitor the condition.
Switching module temperature sensor 
exceeds major threshold 
Major  STATUS LED red
Syslog message and SNMP trap generated.
Power down the module.
Switching module temperature sensor 
exceeds minor threshold 
Minor
STATUS LED 
orange
Syslog message and SNMP trap generated.
Monitor the condition.