PRO-READ ENCODER REGISTER
Before removing the ProRead receptacle, ensure that the ProRead register is 
programmed for three-wire mode.
If a two-wire conductor cable is connected to a "potted" ProRead encoder 
register, replace the register with a three-wire register. 
Reprogramming a ProRead encoder from 2-wire to 3-wire
It may sometimes be necessary to reprogram a ProRead register encoder from 2-
wire to 3-wire mode. Accomplish this with a Neptune ProRead field programmer.
A basic overview of the steps is as follows:
1
Connect to the remote receptacle with the field programmer.
2
Interrogate the encoder register to determine its operating mode (2 or 3-wire).
3
Reconfigure the encoder register to make it operate in 3-wire model.
4
Verify that the reconfiguration was successful by looking at the Field 
Programmer screen. The OM field should be 3W (see below).
Table 2.1 
Before Reprogramming 
(2-wire mode)
After Reprogramming 
(3-wire mode)