Landis+Gyr Technology Inc. EG6R3S2 User Manual
`çããÉêÅá~ä=~åÇ=fåÇìëíêá~ä=jÉíÉê=jçÇìäÉ=fåëí~ää~íáçå
`ÉääåÉí=d~ë=jçÇìäÉ=~åÇ=jÉíÉê=fåëí~ää~íáçå=dìáÇÉ
SJNP
1
Follow the steps in ʺTo Begin C&I Meter Module Installationʺ on page 6‐1.
2
Remove the tamper caps and index cover from the original meter. Remove all
of the original gasket material. Clean the gasket surface on the meter with a
wire brush and gasket scraper.
of the original gasket material. Clean the gasket surface on the meter with a
wire brush and gasket scraper.
3
Open the package containing the Meter Module, screws, and battery.
Figure 6.22 Sprague/Actaris: screw kit
4
Open the bag containing the battery. Carefully remove the battery.
5
Open the Meter Module, taking care to avoid pulling on the cables.
6
Connect the battery to the Meter Module. Assemble the battery into the
retaining clip on the metal bracket.
retaining clip on the metal bracket.
7
Connect the programming cable from the handheld computer to the
programming port on the replacement Meter Module. Program the Meter
Module. Check the handheld for successful programming.
programming port on the replacement Meter Module. Program the Meter
Module. Check the handheld for successful programming.
8
Slide the metal bracket (not the green circuit board) into the slots of the
clamshell (one of the clamshell halves has slots on opposite sides of the
interior). If you are looking down into the slots, the battery clip should be
towards the top ‐ the large capacitors on the circuit board go deep into the
clamshell. Assemble the Meter Module halves together with the four small
self‐tapping screws provided. The torque requirement is 6‐10 inch pounds.
Ensure that the gasket is in place and the wires are not pinched. Install the
tamper seals.
clamshell (one of the clamshell halves has slots on opposite sides of the
interior). If you are looking down into the slots, the battery clip should be
towards the top ‐ the large capacitors on the circuit board go deep into the
clamshell. Assemble the Meter Module halves together with the four small
self‐tapping screws provided. The torque requirement is 6‐10 inch pounds.
Ensure that the gasket is in place and the wires are not pinched. Install the
tamper seals.
9
Slide the bracket between the index cover and the meter.
Check condition of the index for looseness of index pointers on shaft, cracks on face
enamel, or peeling. Replace the index if dials are loose or if enamel is cracked or loose.
enamel, or peeling. Replace the index if dials are loose or if enamel is cracked or loose.