1
Follow the steps in ʺTo Begin C&I Meter Module Installationʺ on page 6‐1.
2
Remove the tamper caps and index cover from the original meter. Remove all 
of the original gasket material. Clean the gasket surface on the meter with a 
wire brush and gasket scraper. 
3
Open the package containing the Meter Module, screws, and battery.
Figure 6.22 Sprague/Actaris: screw kit
4
Open the bag containing the battery. Carefully remove the battery. 
5
Open the Meter Module, taking care to avoid pulling on the cables. 
6
Connect the battery to the Meter Module. Assemble the battery into the 
retaining clip on the metal bracket.
7
Connect the programming cable from the handheld computer to the 
programming port on the replacement Meter Module. Program the Meter 
Module. Check the handheld for successful programming. 
8
Slide the metal bracket (not the green circuit board) into the slots of the 
clamshell (one of the clamshell halves has slots on opposite sides of the 
interior). If you are looking down into the slots, the battery clip should be 
towards the top ‐ the large capacitors on the circuit board go deep into the 
clamshell. Assemble the Meter Module halves together with the four small 
self‐tapping screws provided. The torque requirement is 6‐10 inch pounds. 
Ensure that the gasket is in place and the wires are not pinched.   Install the 
tamper seals.
9
Slide the bracket between the index cover and the meter.
Check condition of the index for looseness of index pointers on shaft, cracks on face
enamel, or peeling. Replace the index if dials are loose or if enamel is cracked or loose.