Chapter 1 - Gridstream Enhanced Cellular Overview 
User Guide
98-1723 Rev AB
11
ZigBee Support
The Gridstream Enhanced Cellular communication module supports an integrated ZigBee system on 
the chip. This enables the endpoint to communicate via Smart Energy Profile with other ZigBee 
enabled devices.
Retrieving Data
The endpoint is capable of delivering data via an On Request Read (ORR) or autonomously (period-
ically reported). 
Availability of the following features depends on meter configuration. On Request Reads (ORR) 
available with this endpoint are:
Register Data (Standard Table 23) which includes consumption, demand and TOU values
Load Profile or Interval Data. Multiple Load Profile channels will be available for meters 
that support it (Standard Table 64 FOCUS AXe)
Revenue Integrity Services which includes instantaneous measurements related to line 
voltage, current and phase angle
Availability of the following features depends on meter configuration. Options for periodic reported 
data with this module include:
Register Data & Status Flags (Standard Tables 23 & 3) which includes consumption, 
demand, TOU values and meter status
Load Profile or Interval Data & Status Flags (Standard Tables 64 & 3) which includes 
interval data and meter status
Demand Reset
When the Command Center Host delivers a Demand Reset command, the communication module 
passes the command to the meter, which performs the Demand Reset on the meter. The endpoint 
then passes the previous demand data captured by the meter (Standard Table 25) to the Host for pro-
cessing. Scheduling the demand resets may be performed through the Command Center Host. See 
the chapter on Demand Resets in this manual for further instructions.
Power Outage/Restoration
When an outage greater than 30 seconds occurs, the meter uses an early power failure signal to alert 
the communication module to disconnect from the meter's power immediately. The communication 
module saves critical module data to non-volatile memory and creates and sends a power outage 
message. This message includes the following information:
LAN ID
Outage timestamp
Outage count