Chapter 5 - Managing Endpoints
Landis+Gyr
44
98-1723 Rev AB
User Guide
Defined Addressing Group. By default, this process runs once an hour. This schedule can be changed 
in the Process Settings.
A cellular module will transition to Configure during reconfiguration. When the cellular module 
responds to the configuration request, the module status will transition back to Normal. 
Enhanced Cellular Set Network Configuration Command
The Modify Network Program command allows the user to modify the cellular endpoint's communi-
cation parameters from Command Center. Changing any of these values to invalid values will break 
the cellular endpoint's communication with the HES and there's currently no other way fix it over the 
air. The meter will need to be configured in diag. mode.
As shown below, the same ports are used on both module and HES. Inbound for module will be out-
bound for HES and vice versa. So if the user changes the ports, the following M2M Adapter config 
files will also need to be modified to use the new ports:
..\Landis+Gyr\M2MAdapter\M2MListener\LandisGyr.CellularNMS.Listener.exe.config - 
this config file has HES and firmware download ports.
..\Landis+Gyr\M2MAdapter\HeartBeatListener\LandisGyr.CellularNMS.HeartbeatCommunic
ation.exe.config - this config file has the heart beat ports.
To use the command the user has to do the following:
1. Create a network program using the menu option Setup > Network Program.
2. Issue Set Network Configuration command from EIS screen > Manage tab or from the group 
commands page.
The functionality listing/adding/editing/deleting a network program is similar to that of other config 
pages like configuration groups.
 Figure 5 - 10. Network Program Details Page