K-jump Health Co. Ltd. TEMPONITOR User Manual

Page of 6
4
5
6
7
Setting °C or °F
sensor
Adhesive tape
sensor
Adhesive
 tape
Period for Heat Equilibrium 
Room
temperature
Skin surface 
temperature
5~10 min.
Start data reading
The KD 2101 provides user to select the unit
in either °C or °F by following steps:
1. Click the "O/I" key to turn on the device. 
2. The LCD will show all 
segments first.
3. Then the LCD will show 
last measured data.
4. As the "memory" icon
disappears; now, you 
have 5-second period
for the setting; keep 
pressing the O/I key 
and the unit will switch 
to either °C or °F you
want.
(Keep pressing
 O/I key for 2 sec)
Start Measurement
Room Temperature Affects Skin
Temperature
Skin is major organ for maintenance of body 
temperature; either hot or cold environment
will cause skin temperature to rise or to fall.
It is recommended that subject is kept in a
comfortable room temperature (usually 
22~28°C (71.6~82.4 °F).  Also, after
applying the sensor, a 5~10 minutes waiting 
for temperature equilibrium between the 
sensor and your skin surface will be 
necessary before taking the first 
measurement.
Notice
When using the skin sensor or armpit 
sensor,  wipe body skin with a dry towel .
1. Turn on the device, the device will
perform system checking automatically 
until "ready for detecting" as figure:
2. Place the reader on the upright  direction 
of the transmitter around  3~4 cm (1,5 
inches) distance.
3. Click the "start key", the device starts 
scanning the patch temperature with 
flashing "---".
4. The result is then shown on the LCD with 
2 beep sounds.  Measurement is 
completed.
5. For another reading, just repeat the steps 
mentioned above.
with
in 3
cm
(1.5
inch)
Start
key
Insert the ear
tape sensor
into ear
canal.
Applying the Sensor
MEMORY
MEMORY
Applying the Sensor
For fixing the patch, a dressing (or surgical) 
adhesive tape will be needed. A high quality 
tape without side-effect is recommended 
since long period (usually 24~48 hr)
adhesion.
1. Apply the temperature sensor to ear 
canal, armpit or abdominal area below
navel (depended on different types).
2. For armpit or body skin types, fixing the
sensor by medical adhesive tape(s).  Be
sure the firmness.
3. Subject is allowed to dress cloth rather 
than naked.
4. For infant or baby, the sensor under 
diaper will benefit the measurement 
result since warmer measurement 
environment.
Maintenance
Do not modify or
disassemble the 
reader or sensor..
Do not twist the
sensor.
Use a cloth
moistened with 
water or neutral
detergent to 
clean the body
of the unit and
then wipe it dry.
Avoid thinner,
benzene, and
other harsh
cleaners.
Avoid storage in
hightemperature,
direct sunlight, high
moisture, and dust.
Remove the 
batteries if the
unit will not be 
used for a long
time.
Do not drop the 
unit.
37.0
37.0
37.0
37.0