6.2  GUI Alarm 
Problem 
Check Point 
Solution 
DC Current 
If  the  same  alarm  occurs  after  reset  Power,  request 
technical support. 
Temperature 
Execute  of  System  Reset  (NCU)  on  Network  Setup 
page.  If  the  same  alarm  occurs  request  technical 
support.   
ASD 
Check Isolation and DL/UL Input power.. 
General 
Heartbeat 
Check the connection of the Remote NMS Cable. 
Check the interval of Heartbeat on the WEB GUI 
DL Input Power 
DL  Input  alarm  can  be  the  result  of low  signal  level 
from the donor antenna circuit. 
Tune Femto output level and/or reduce line loss. 
DL Output Power 
Check DL input Power. 
If  input  power  exceeds  max  input  power  install  an 
attenuator on the donor antenna feed line. 
Downlink 
DL Return Loss 
Return  loss  alarm  is  the  result  of  o  poorly  matched 
antenna  circuit.  The  equipment  is  almost  never  the 
reason for return loss issues. A good quality 50 ohm 
load placed over the equipment server port or donor 
port will extinguish the alarm and prove the alarm is 
caused by some external antenna issue. 
Uplink 
UL Output Power 
If  the  UL  Input  Power  is  too  high,  suspect  excessive 
mobile  TX  power.  Determine  root  cause  of  high 
mobile TX power.