BMI Technologies Inc. RFVI User Manual

Page of 85
DRAFT G FORCE PLUS RF Instruction Manual 
 
 
Doc #RF1 Rev.9 
81 
Apr/08 
Comment 
Comment field for reference only (i.e. year of purchase). 
Settings Tab 
 
Impact Hard Threshold (G) 
Threshold for hard impact detection for the vehicle (hard 
impacts have greater intensity and shorter duration).  See 
“RECOMMENDED SETTINGS”. 
Impact Hard Samples 
Number of samples measured for hard impact detection for the 
vehicle.  See “RECOMMENDED SETTINGS”. 
Impact Soft Threshold (G) 
Threshold for soft impact detection for the vehicle (soft 
impacts have lesser intensity and longer duration).  See 
“RECOMMENDED SETTINGS”. 
Impact Soft Samples 
Number of samples measured for soft impact detection for the 
vehicle.  See “RECOMMENDED SETTINGS”. 
(Impact) Lift Interrupt 
From Authorization Group settings.  Yes for Lift Interrupt 
when Impact is detected.  No for no Lift Interrupt when 
Impact is detected. 
(Impact) Secondary Alarm 
From Authorization Group settings.  Yes for Secondary Alarm 
when Impact is detected.  No for no Secondary Alarm when 
Impact is detected. 
(Impact) Interrupt/Alarm Delay 
(seconds) 
From Authorization Group settings.  Number of seconds 
before Lift Interrupt or Secondary Alarm engages when 
Impact is detected. 
(Impact) Automatic Reset 
From Authorization Group settings.  Yes if Automatic Reset 
occurs when Impact is detected.  
Hour Meter at Installation 
Vehicle hour meter reading when Vehicle equipped with a G 
FORCE PLUS/RF Vehicle Monitor is put into service. 
G FORCE Hour Meter 
G FORCE PLUS/RF Vehicle Monitor Hour Meter reading 
determined by PM Time Tracking Method. 
Actual Vehicle Hours 
Addition of values from Hour Meter at Installation and G 
FORCE Hour Meter.  
Date of Last PM 
The most recent date of a Maintenance Work Order identified 
with a Scheduled PM reason.  If no Maintenance Work Orders 
are entered, this field will remain blank.  
Next PM Due in (hours) 
Number of hours that the next scheduled PM is due for the 
Vehicle. 
PM Time Tracking Method 
From Authorization Group settings.  Method of tracking time 
for scheduled Preventative Maintenance purposes:  Login or 
Motion. 
PM Interval/Frequency every (hours) 
From Authorization Group settings.  Value used to update 
when the next scheduled Preventative Maintenance should be. 
Battery Nominal Voltage 
Nominal battery voltage for the Vehicle. 
OK To Charge Threshold 
Upper limit of the OK To Charge battery range in specific 
gravity points. 
Must Charge Threshold 
Upper limit of the Must Charge battery range in specific