Tyco Safety Products / Software House PI26 User Manual

Page of 138
Testing the apC/8X Installation
apC/8X Technical Manual
B
-
5
RM LEDs
Each RM reader has three LEDs: red, green, and amber. The various 
conditions indicated by these LEDs are described in Table B.2.
Note: *To set Reader LEDs to Normal (default) or Alternate 
indications, select Diagnostics System (Diag) utility> Dialup > 
ReaderLEDSettings > Entry Value = (normal) or (alternate).
Table B.2: RM Reader LED Indications
Red LED
Amber
Green 
Indication
Brief flash
Brief flash
Brief flash
Power up
Off
Off
Off
Online (Alternate indication)*
Off
On
Off
Online (Normal indication)*
On
Off
Off
Offline or reader tamper
Solid for 1 sec.
Off
Off
Access denied (Normal indication)*
Fast flash for 2 sec.
Off
Off
Access denied (Alternate indication)*
Off
Off
On
Access granted or door unlocked 
(Alternate indication)*
Off
Off
Fast flash
Access granted (Normal indication)*
Off
Off
Slow flash
Door unlocked (Normal indication)*
Off
Slow flash
Off
Enter second card (escorted access only)
Off
Fast flash
Off
Enter PIN 
Off
Fast flash
Off
Enter floor # (systems configured for 
elevator control only)
Flash w/ each key 
press
Off
Flash w/ each key press
Keypad input
Slow flash
Off
Off
Reader not configured
Fast flash
Fast flash
Fast flash
Alarm: door forced/held open
On
On
On
Error condition: Remove power to prevent 
damage to RM