> If power indicator does not illuminate, verify the presence of AC power at the input to the power supply.
Do not plug the FEBnet Node into an outlet that is controlled by an on/off switch.
> If AC power is present, check that the power supply is operating by measuring the voltage at the circular
output jack. It should be 6 VDC.
> If networking problems occur, test the FEBnet Node network wiring to determine if a short circuit exists. Measure
the resistance between the A and B terminals of each FEBnet Node. Also measure between the A terminal and
Ground terminals as well as between the B terminal and Ground terminals. A measurement of less than 100
Ohms indicates a possible short circuit. Trace out the cable to locate the short.
TROUBLESHOOTING