[Voice prompt – Periodic test interval,
1 for 1 day,
2 for 7 days,
FACTORY SETTING 3 for 30 days]
3.  Enter 1, 2 or 3
[Voice prompt 1 – Every day] [Voice prompt 2 – Every 7 days] [Voice prompt 3 – Every 30 days]
4.  Enter “#” (to exit programming mode)
[Voice prompt – Programming complete]
5.  Slide Programming Switch to “Normal Operation” 
[Voice prompt – “Emergency Call Mode”]
Option #9 – Reset To Factory Settings
1.  Enter (Passcode) – XXXX then “
**
” (Default is 1234
[Voice prompt – Option Mode]
2.  Enter 9 
[Voice prompt – Reset to factory settings,
1 for YES – 3 for NO]
3.  Enter either 1 or 3
[Voice prompt 1 – YES] [Voice prompt 3 – NO]
4.  Enter “#” (to exit programming mode)
[Voice prompt – Programming complete]
5.  Slide Programming Switch to “Normal Operation” 
[Voice prompt – “Emergency Call Mode”]
Note: The telephone numbers are erased, so if the Emergency button is pushed, you will hear the 
dial tone and then “Hanging Up”
REMOTELY PROGRAMMING THE System:
The System can be remotely programmed over a telephone line in one of two ways – Standard and Unaided 
Remote Programming.
Standard Method:  
1.  Simply call the number of the residence where the System is connected. 
2.  Have the user slide the switch at the back of the base unit to “Programming Mode”. 
3.  Then, proceed to program the System as needed with the touch-tones of the phone on which you are 
calling from. 
4.  Have them slide the switch back to Normal Operation when done.
 Unaided Remote Programming:
1.  The dealer calls the customers phone number that the CaretakerSentry is installed on.
2.  The dealer allows the phone to ring 1 ring cycle - (equivalent to 1 ring back tone - about 6 seconds of 
ringing).
3.  The dealer then hangs up.
4.  The dealer waits 10 seconds and dials the customer phone number again.  The CaretakerSentry sees this 
second call within a 30 second period and immediately answers the phon.
•  The CaretakerSentry will only start this 30 second timer - waiting for a second call to ring the phone 
ONLY if the phone only rings 1 time. If the phone rings more than 1 time, the CaretakerSentry unit will 
not start the timer and will NOT wait for the second call - feature is canceled and reset.
5.  As soon as the CaretakerSentry answers the call, [voice prompt – programming mode] is played.
6.  The dealer enters the 4 digit passcode and then CaretakerSentry enters programming mode (unit will 
program normally).