The configuration key app/failure ID/alarm ID defines the value of the alarm
ID to send to Wiegand or Dataclock. This ID permits to distinguish between a
user ID and an error ID. To be validated, configuration key app/failure ID/
enabled
 must be set to 1.
In Wiegand and Dataclock the alarm ID is sent like other Failure Ids. See the
documentation  MorphoAccess
®
 Remote Messages Specification for a
description of the packet format in UDP and RS485.
Tamper Alarm Level
app/tamper alarm/level 
0  Anti-pulling and anti-tamper switches ignored.
1  An alarm message is sent to the controller by the same channel as the 
access control result message (if enabled).
2  In addition to previous level, the terminal buzzer outputs an audible alarm 
signal, and the terminal status LED displays a red blinking light.
Tamper Alarm ID
app/failure ID/alarm ID
 
app/failure ID/enabled 1 (Enabled)
 
                       0 (0 - 2)
       65535 (0 - 65535)
                                                           1