The Night Probe controller provides a four-position switch for lighthead movement and a push-on/push-off
switch for lamp control.  The four-position switch provides either single-speed movement or Pulse Width
Modulated (PWM) acceleration from slowest to fastest speed. This feature is controlled by the position of
the PWM configuration jumper (JP1) which is located inside the Interface Module (see Figure 3).  When
the PWM configuration jumper is set to the OFF position depressing and holding the four-position switch in
the LEFT, RIGHT, UP or DOWN direction will cause the Night Probe  lighthead to rotate in the appropriate
direction in single speed mode.  When the jumper is set to the ON position the Night Probe  lighthead will
accelerate from it's slowest speed to full speed over a two second period and stop instantly when the
switch is released.  This mode allows for very precise positioning of the light.
The NightProbe   130 RF is designed for use with an optional RF Remote Control.
The NP 130 RF Remote Control comes complete with battery installed.  Simply pull the battery activation
tab at the borrom of unit.
The NP 130 control must be trained to recognize your remote unit.  After installation, apply
power to your np 130 system.  Depress and hold the training switch located through a hole
in the case near the antenna.  While holding the training switch, depress and release the small
(ON/OFF) switch on the remote unit.  Release the training switch and test the unit.  The RF Remote
Control operation is the same as that described for the wired control.
This device complies with Part 15 of the FCC Rules.  Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
The user is cautioned that changes or modifications not expressly approved by CODE 3 for compliance
could void the user's authority to operate this equipment.
Figure 5
Operation
Figure 4
The NightProbe  is designed for Electro-mechanical use.
WARNING! 
CONTROLLER PENDANT AND