RadioFrame Networks Inc DH2 User Manual

Page of 164
Method of Procedure 
Operations and Maintenance 
124 
RFN_3.1 Beta
 
7.3.3.2 
Airlink Chassis Unit 
ACU front ports 
Description 
RJ45 Port 1 
NCU—connects the ACU to the NCU 
RJ45 Ports 2-8 
not currently used 
EIA-232 9-pin serial port 
for debugging—Customer Service use only 
ACU back ports 
 
Ports 1-8 (RJ45) 
RFUs—up to 8 RFUs may be connected to the ACU 
5MHz/1PPs  IN 
not currently used 
5MHz/1PPs  OUT 
not currently used 
GPS ANT 
not currently used 
 
Each card installed in the front and back of the ACU has two LEDs: Power (top) 
indicates power, and Status (lower) indicates the status of the card. Each RJ45 
port has two LEDs: Link (right) indicates Ethernet connectivity, and Activity (left) 
blinks to indicate Ethernet activity. All LEDs should light as green. For all other 
conditions, refer to the following table. 
Indication 
Possible failure 
Corrective action 
Power or Status LEDs 
for cards installed in 
front or back of ACU are 
not lit 
no power to ACU 
 
Verify that the power cord is 
installed and properly seated. 
 
Verify that the power source is 
operational (120VAC or  
–48VDC). 
 
Contact Customer Support. 
Status LED is red—any 
card 
card is not operational 
 
Remove and reseat card. 
 
Contact Customer Support. 
 failed 
initialization 
 
Reboot the system: unplug the 
ACU, and plug it in again. Boot 
up may take several minutes. 
 
fan is not working 
 
Verify that the fan is 
operational.