RadioFrame Networks Inc DH2 User Manual

Page of 164
Method of Procedure 
Operations and Maintenance 
132 
RFN_3.1 Beta
 
‘Unable to Key BR’ alarm severity 
Description 
minor 
An iDEN RadioBlade or 802.11b RAP has failed. 
major 
An RFU has failed. 
critical 
A card in a chassis unit has failed (except for the RLIC, 
which returns alarm information.) 
7.5.3 
System Manager Alarms 
The first table below lists System Manager alarms that are sent to the OMC, the 
OMC alarm message, and the severity of the alarm. The second table describes 
all System Manager alarms, and what action is required, if any, to resolve the 
problem. 
 
OMC Alarm 
System Manager Alarm 
Severity 
BOARD DISABLED 
PEER LOSS 
MINOR (RAP only) 
BOARD DISABLED 
PEER LOSS 
CRITICAL 
(any board except RAP) 
EXCESS RESETS 
EXCESS RESETS 
CRITICAL 
ENABLE WAIT 
BR ENABLE FAIL 
MINOR 
NO SPAM IN APC 
APC NO SPAM 
CRITICAL 
RADIO BLADE LOST  IDENRB LOSS 
MINOR 
RFU DISABLED 
LOST RFU 
MAJOR 
 
Alarm 
Description 
Action 
5MHz CLOCK 
RIC or RLIC temporarily lost the 1 PPS 
reference. 
No action required. 
ALARMS CLEARED 
Alarm Manager was cleared using the Clear 
Alarms button. 
No action required. 
APC NO SPAM 
There are more BRs than the current SPAM 
resources can support.  
Add more SPAMs as 
required. 
APC SLOT MISS 
Slot mismatch detected on APC or NPC.  
Causes a slot sync procedure three times.  
If the slot still is not found, generates the 
alarm APC SYNC FAIL. 
 
APC SYNC FAIL 
APC SLOT MISMATCH is not able to 
recover after three attempts.  
Causes a system reset.  
 
ASSGN FAILURE 
More than three consecutive assignment 
failures occurred on a BR without any 
successful calls in between.  
The BR is locked out.