RadioFrame Networks Inc DH2 User Manual

Page of 164
RadioFrame System 
Operations and Maintenance 
RFN_3.1 Beta
  
133 
Alarm 
Description 
Action 
BAD RB SLOT 
RB reported a slot number that is out of 
range (1-8). 
Replace either the RFU 
or the RB. 
BAD VGA 
1180s received from the RB have a 
consistently high Gain setting, even in the 
absence of any signal indicating Rx 
Calibration issues.  
RIC will attempt to reset the RB three times, 
and then generates a Calibration alarm. 
 
BR ACTIVITY 
Not currently used. 
No action required. 
BR ENABLE FAIL 
BR remained disabled for more than 30 
minutes. 
Causes the BR to go into permanent Error 
mode and will not participate in further fault 
recovery procedures. 
 
BR STARTUP FAIL 
Not currently used. 
No action required. 
CHNL SETUP ERR 
iSC channel setup (channelSetup) is invalid 
or inconsistent.  
Causes the BR to be de-keyed and to return 
to LEI mode to restart the channel 
allocations with the iSC. 
 
COMMANDED 
RESET 
System Reset was initiated via System 
Manager. 
Causes a system reset.  
 
COVERAGE HOLE 
One BR in a sector has fewer RBs than 
other BRs in that sector. 
The BR that is short of Radio Blades has 
locked. 
 
DHRB RESET 
A problem in the DHRB has caused it to 
reset. 
No action required. 
DHRB TASK EXCEP 
Task Exceptions has occurred for some task 
on the DHRB. 
DHRB resets. 
No action required. 
DSP 1180 FLOOD 
The RB 1180 DSP address is flooding all 
ports. 
Sends a Stop Tx command to the RB and 
causes a system reset. 
 
DSP HPI ERROR 
Problem in accessing HPI interface for a 
DSP. 
If errors go beyond a threshold, SPAM is 
reset. 
 
DSP LOAD ERROR 
DSP software not found. 
DSP was not initialized. 
Check the ffs files etc.