RadioFrame Networks Inc DH2 User Manual
RadioFrame System
Pre-Installation
RFN_3.1 Beta
37
Operating Ambient Temperature
iDEN Interface
iSC-3
-40ºF to +185ºF
(-40ºC to +85ºC)
-22ºF (-30ºC)
+140ºF (+60ºC)
EAS
-40ºF to +185ºF
(-40ºC to +85ºC)
+32ºF (0ºC)
+122ºF (+50ºC)
CSU
-40ºF to +185ºF
(-40ºC to +85ºC)
+32ºF (0ºC)
+122ºF (+50ºC)
Power Plant
Rectifier
-40ºF to +185ºF
(-40ºC to +85ºC)
+32ºF (0ºC)
Sea level to
4800’: 122ºF
(50ºC)
4800’: 122ºF
(50ºC)
4800-7000’:
113ºF (45ºC)
113ºF (45ºC)
7000-10,000’
+104ºF (+40ºC)
+104ºF (+40ºC)
Battery
77ºF (+25ºC)
-40ºF (-40ºC)
+122ºF (+50ºC)
* Altitude: -200 to +8,000 feet above mean sea level; above 8000’ reduce maximum operating ambient
temperature by 2ºC per 1000’ to a maximum of 13,000’.
temperature by 2ºC per 1000’ to a maximum of 13,000’.
System
Unit
Relative Humidity
RadioFrame System
NCU
10-90% non condensing
ACU
10-90% non condensing
iDEN Interface
iSC-3
5-90% non condensing
EAS
5-90% non condensing, non-operating
0-90% non-condensing, operating
CSU
5-90% non condensing
Power Plant
Rectifier
5-90% non condensing
Battery
N/A
3.3.7 Heat
Load
System
Unit
BTUs per Hour
RadioFrame System
NCU
700
ACU
700
iDEN Interface
iSC-3 (1)
140
iSC-3
(2)
140
EAS
170
CSU
17
Power Plant
Rectifier
13.5 KBTUs (max)
Battery
683