RadioFrame Networks Inc DH2 User Manual
RadioFrame System
Pre-Installation
RFN_3.1 Beta
41
3.4.1 Mounting
Remote ACUs are located in telco rooms or other closets throughout the building,
mounted in 19” EIA-standard compliant racks or equivalent. Any other method
used to mount the remote ACU is not approved, and could void the warranty on
the product and other components in the RFS.
mounted in 19” EIA-standard compliant racks or equivalent. Any other method
used to mount the remote ACU is not approved, and could void the warranty on
the product and other components in the RFS.
NOTE: The ACU may be placed on a flat surface only if the front and back of the
unit are accessible and if the side vents are not blocked. In this case, the ACU is
not secured and, therefore, is not rated to withstand any level of earthquake, and
the warranty may be voided.
unit are accessible and if the side vents are not blocked. In this case, the ACU is
not secured and, therefore, is not rated to withstand any level of earthquake, and
the warranty may be voided.
Currently, the remote ACU does not include a Universal Power Supply (future
enhancement). Grounding of the remote ACU is not required by RadioFrame
Networks and is the responsibility of the RFN customer or its customer. A
bonding ground point for protective earth grounding is provided; #6 screw with
internal sems washer.
enhancement). Grounding of the remote ACU is not required by RadioFrame
Networks and is the responsibility of the RFN customer or its customer. A
bonding ground point for protective earth grounding is provided; #6 screw with
internal sems washer.
3.4.2 Clearances
•
Dimensions: 19" wide x 7" high x 13" deep (approx.)
3.4.2.1 Back
•
7”
3.4.2.2 Front
•
12”
3.4.2.3 Sides
•
Left side (facing unit): 0”; right side: 2”
3.4.2.4 Above
•
Above: 0”
3.4.3 Weight
•
27 lbs (fully loaded)
3.4.4 Power
•
100-240 Volts AC, 47-63 Hz, 8-3.5A , or
•
Negative 48-56 Volts DC, 11A