Method of Procedure 
Pre-Installation 
48 
RFN_3.1 Beta
 
3.8 URU 
3.8.1 Mounting 
The URU can be placed on any flat surface or mounted using the provided 
mounting screws. The URU must be located within 12 feet of an approved power 
source.  
3.8.2 Clearances 
• 
Dimensions: 5.5" wide x 1.25" high x 5.5" deep (approx.) 
3.8.2.1 Back 
• 
2” 
3.8.2.2 Front 
• 
3” 
3.8.2.3 Sides 
• 
1” 
3.8.2.4 Above 
• 
Above: 0” 
• 
Below: 0.125” 
3.8.3 Weight 
• 
1.5 lbs  
3.8.4 Power 
• 
100-240 Volts AC converts to negative 48VDC (power cord provided)* 
* The URU uses –48 VDC. The input voltage connector on the URU requires 
–48 VDC. The provided power cord includes an external isolated power 
supply that converts 100-240 VAC to –48 VDC. The input supply requires 48 