RadioFrame Networks Inc DH2 User Manual

Page of 164
RadioFrame System 
Installation 
RFN_3.1 Beta
  
75 
 
 
Figure 25 
Connect the RFU to the ACU, then ensure that the RFU is receiving 
power and connectivity from the ACU. 
4.4.3 
Insert the RadioBlades and RAPs into the RFU 
The iDEN RadioBlades and 802.11 RAPs are shipped several to a box in 
individually wrapped antistatic packaging. Each box of RadioBlades/RAPs 
includes a disposable antistatic wrist strap to be used when inserting the 
RadioBlades/RAPs into the RFU. Refer to the site documentation for the exact 
slot location of each RadioBlade/RAP within the RFU. 
1  Unwrap 30 cm (12”) of the disposable wrist strap and wrap the adhesive side 
around your wrist.  
2  Unroll the rest of the band and remove the liner from the copper tape. 
3  Attach the copper tape to the metal card cage inside the RFU. 
4  Un-package the iDEN RadioBlades to be inserted in the RFU. 
5  Insert the iDEN RadioBlades, one at a time, into the specified slots (1 through 
7) in the RFU until the connector on each RadioBlade seats firmly into the 
back of the RFU (see the following illustration). 
6  Unscrew the antenna from each iDEN RadioBlade, one at a time, and place 
the antennas on an antistatic surface (see the second following illustration).