RadioFrame Networks Inc MCRB10 User Manual
MC-Series System Installation & Testing
Scheduled and Unscheduled Maintenance
82
RadioFrame Networks, Inc.
Additional Info
:
dspId or 0xff for hpi error
Repair Action
: Check preceding alarms as to the cause of the SPAM reset. Reseat SPAM, if
problem persists, replace BPC.
7.4.4.35
Network memory shortage
ID
:
4106
Service
: iden
Severity
: critical
Cause
:
Out of Memory
System Reaction
: System
Reset
Additional Info
: cluster
level
Repair Action
: Internal problem with the network memory pool. Replace BPC.
7.4.4.36 Invalid
RB
Slot
ID
:
4108
Service
: iden
Severity
: minor
Cause
:
Equipment Malfunction
System Reaction
: Reset
RadioBlade
Additional Info
: None
Repair Action
: Reseat RadioBlade. If problem still persists, replace RadioBlade or move to
another slot. If problem still persists, replace RBS.
7.4.4.37
DSP Tx null PDU
ID
:
4110
Service
: iden
Severity
: minor
Cause
:
Loss of Signal
System Reaction
: SPAM
Reset
Additional Info
:
APC Mac address
Repair Action
: This is a result of the DSP sending incorrect data to the RadioBlade. Ignore if
happening infrequently. Check for intermittent cable connections. Possibly a result of timing
problems on the NPC.
problems on the NPC.
7.4.4.38 Interference/Calibration
ID
:
4111