RadioFrame Networks Inc MCRB10 User Manual

Page of 167
MC-Series System Installation & Testing 
Scheduled and Unscheduled Maintenance 
82 
RadioFrame Networks, Inc.
 
Additional Info
dspId or 0xff for hpi error 
Repair Action
:  Check preceding alarms as to the cause of the SPAM reset. Reseat SPAM, if 
problem persists, replace BPC. 
7.4.4.35 
Network memory shortage 
ID
:  
 
 
4106 
Service
:   iden 
Severity
:   critical 
Cause
:   
Out of Memory 
System Reaction
: System 
Reset 
Additional Info
: cluster 
level 
Repair Action
:  Internal problem with the network memory pool. Replace BPC. 
7.4.4.36 Invalid 
RB 
Slot 
ID
:  
 
 
4108 
Service
:   iden 
Severity
:   minor 
Cause
:   
Equipment Malfunction 
System Reaction
: Reset 
RadioBlade 
Additional Info
: None 
Repair Action
:  Reseat RadioBlade. If problem still persists, replace RadioBlade or move to 
another slot. If problem still persists, replace RBS. 
7.4.4.37 
DSP Tx null PDU 
ID
:  
 
 
4110 
Service
:   iden 
Severity
:   minor 
Cause
:   
Loss of Signal 
System Reaction
: SPAM 
Reset 
Additional Info
APC Mac address 
Repair Action
:  This is a result of the DSP sending incorrect data to the RadioBlade.  Ignore if 
happening infrequently.  Check for intermittent cable connections. Possibly a result of timing 
problems on the NPC. 
7.4.4.38 Interference/Calibration 
ID
:  
 
 
4111