RadioFrame Networks Inc MCRB10 User Manual

Page of 167
MC-Series System Installation & Testing 
Scheduled and Unscheduled Maintenance 
RadioFrame Networks, Inc.
  
83 
Service
:   iden 
Severity
:   minor 
Cause
:   
Degraded Signal 
System Reaction
: Reset 
RadioBlade 
Additional Info
Radio Blade Index 
Repair Action
:  This is a result of either an interference source or the RadioBlade is going out of 
Calibration.  Lock or swap RadioBlades with that carrier. If the problem follows the carrier, most 
likely interference. If the problem follows the RadioBlade, most likely out-of-cal RadioBlade is the 
source. 
Note: This alarm does not have a clear 
7.4.4.39 
RB Failed to synchronize 
ID
:  
 
 
4112 
Service
:   iden 
Severity
:   minor 
Cause
:   
Timing Problem 
System Reaction
: SPAM 
Reset 
Additional Info
: None 
Repair Action
:  After 3 attempts to re-synchronize the RadioBlade, this alarm is issued and the 
SPAM is reset.  If problem persists, replace RadioBlade or replace SPAM. 
Note: This alarm does not have a clear 
7.4.4.40 
RB Error state 
ID
:  
 
 
4113 
Service
:   iden 
Severity
:   major 
Cause
:   
Equipment Malfunction 
System Reaction
: RadioBlade 
Locked 
Additional Info
Radio Blade index 
Repair Action
:  System failed to read EEPROM calibration data from the RadioBlade. Try a 
different slot/RFU or replace RadioBlade. 
7.4.4.41 
Tx DSP not responding 
ID
:  
 
 
4115 
Service
:   iden 
Severity
:   major