RadioFrame Networks Inc MCSERIES10 User Manual

Page of 152
MC-Series System Installation & Testing 
System Configuration Changes 
108 
RadioFrame Networks, Inc.
 
 
Current: 
10Adc 
Insertion Loss: 
≤ 0.25dB 
Freq. Range: 
0-2400MHz 
Mounting: 
Bulkhead 
Operating Voltage: 
+/-60 Volts 
Protected Side Connector: 
N Female 50
Ω 
Replaceable Gas Tube: 
Yes 
Surge Side Connector: 
N Female 50
Ω 
Throughput Energy: 
≤ 2283µJ for 3kA @ 8/20µs Waveform 
Turn-On Voltage: 
+/-180 Volts 
Unit Impedance: 
50
Ω 
Voltage Standing Wave Ratio: 
1.28 : 1 
Weatherized: 
Bellcore #TA-NWT-000487 Procedure 4.11,  
Wind Driven (120 mph) Rain Intrusion. 
 
8.5.6 
RF Feed Throughs (N-type connectors) 
 
514-0001-99 
Terminator, N-M w/ chain 2W 6GHz, 18db max VSWR @ 6GHz 
S.M Electronics P/N:  STN0610C 
8.6  Available Field Replaceable Units 
The MC-Series System has been designed so that Field Repairable Units (FRUs) can be 
replaced to restore normal system operation as quickly as possible. The following table lists 
RadioFrame Networks FRUs. For equipment not supplied by RadioFrame Networks, follow 
standard Nextel policies and procedures for FRU replacement.   
Table 6 
MC-Series System FRUs 
P/N 
Description 
176-0840-00 
iDEN 2-port RadioBlade Transceivers (RB) 
176-0900-00 
BTS Chassis Unit (BIC) 
176-0800-00 
Airlink Chassis Unit (AIC)