RadioFrame Networks Inc MCSERIES10 User Manual
MC-Series System Installation & Testing
Scheduled and Unscheduled Maintenance
RadioFrame Networks, Inc.
61
7.3.1 BIC
LED
Indication
Condition
Corrective action
green normal
condition
none
POWER
not lit
no power to BIC
Verify that BIC circuit breaker on PDU is
ON.
Check power connection to PDU.
Measure power input, and compare with
Measure power input, and compare with
tolerances listed in section 2
“Specifications”.
“Specifications”.
Verify that the power source is
operational.
Contact the TAC: (800) 328-0847
green normal
condition
none
not lit
card(s) not receiving power
Verify power to BIC (see “POWER”
above)
bootup not complete
Allow three minutes (approx.) for bootup
to complete.
red
CRIC
only
only
timing not synchronized
Verify that the GPS LED on iSC-3 is
green.
Verify that the cable is connected from
BIC ERTM port 5MHz/1PPS IN to iSC-3
port 5MHz/1PPS.
port 5MHz/1PPS.
Contact the TAC: (800) 328-0847
STATUS
red
any card
PLLs are not locked
Verify that the STATUS LED on the BIC
CRIC is green
Check the Alarm Manager for PLL LOCK
alarm; wait 3 minutes for PLLs to lock; if
they do not:
they do not:
Verify integrity of Ethernet connection
between BIC and AIC.
Contact the TAC: (800) 328-0847
7.3.2 AIC
LED
Indication
Condition
Corrective action
POWER green
normal
condition
none