MC-Series System Installation & Testing 
Scheduled and Unscheduled Maintenance 
RadioFrame Networks, Inc.
  
61 
7.3.1 BIC 
LED 
Indication 
Condition 
Corrective action 
green normal 
condition 
none 
POWER 
not lit 
no power to BIC 
 Verify that BIC circuit breaker on PDU is 
ON. 
 Check power connection to PDU. 
 Measure power input, and compare with 
tolerances listed in section 2 
“Specifications”. 
 Verify that the power source is 
operational. 
 Contact the TAC:  (800) 328-0847 
green normal 
condition 
none 
not lit 
card(s) not receiving power 
 Verify power to BIC (see “POWER” 
above) 
 bootup not complete 
 Allow three minutes (approx.) for bootup 
to complete. 
red 
CRIC 
only 
 timing not synchronized 
 Verify that the GPS LED on iSC-3 is 
green. 
 Verify that the cable is connected from 
BIC ERTM port 5MHz/1PPS IN to iSC-3 
port 5MHz/1PPS. 
 Contact the TAC:  (800) 328-0847 
STATUS 
red 
any card 
PLLs are not locked 
 Verify that the STATUS LED on the BIC 
CRIC is green 
 Check the Alarm Manager for PLL LOCK 
alarm; wait 3 minutes for PLLs to lock; if 
they do not: 
 Verify integrity of Ethernet connection 
between BIC and AIC. 
 Contact the TAC:  (800) 328-0847 