RadioFrame Networks Inc MCSERIES10 User Manual
MC-Series System Installation & Testing
Scheduled and Unscheduled Maintenance
RadioFrame Networks, Inc.
83
7.4.4.59
Rx DSP Receive failed
ID:
0x1019
Service: iden
Severity: major
Cause:
Loss of Signal
System Reaction:
SPAM Reset
Repair Action:
Problem occurs when DSP stops receiving data from the RadioBlade.
Reseat or Replace RadioBlade.
Reseat or Replace RadioBlade.
7.4.4.60
RB initialization failure
ID:
0x101a
Service: iden
Severity: major
Cause:
Equipment Malfunction
System Reaction:
System Reset
Repair Action:
RadioBlade failed to recover after 3 reset attempts. Replace RadioBlade
and report to RFN for further investigation.
and report to RFN for further investigation.
7.4.4.61
RB initialization error
ID:
0x101b
Service: iden
Severity: major
Cause:
Configuration Customization Error
System Reaction:
Force RadioBlade to Register
Repair Action:
Problem with RadioBlade setting up with wrong address.
7.4.4.62
Access point activation failed
ID:
N/A
Service: wlan
Severity: minor
Cause:
Equipment Malfunction
System Reaction:
No action taken
Repair Action:
Power Cycle or replace Data Host.