Scheduled and Unscheduled Maintenance 
 
MC-Series High-Power System 
  
998--01 
Rev 
X1 
76 
CONFIDENTIAL AND PROPRIETARY 
RadioFrame Networks, Inc. 
 
TRADE SECRET INFORMATION 
7.4.1  ABIC 
Table 22  BIC LED Indications 
LED 
Indication 
Condition 
Corrective action 
green normal 
condition 
none 
POWER 
not lit 
no power to ABIC 
 
 
 
Verify that ABIC circuit breaker on PDU is 
ON. 
Check power connection to PDU. 
Measure power input, and compare with 
tolerances listed in section 2 
“Specifications”. 
Verify that the power source is operational. 
Contact the TAC:  (800) 328-0847 
green normal 
condition 
none 
not lit 
card(s) not receiving power 
Verify power to BIC (see “no power to BIC” 
above) 
bootup not complete 
Allow three minutes (approx.) for bootup to 
complete. 
red 
CRIC only 
timing not synchronized 
Verify that the GPS LED on iSC-3 is green. 
Verify that the cable is connected from BIC 
ERTM port 5MHz/1PPS IN to iSC-3 port 
5MHz/1PPS. 
Contact the TAC:  (800) 328-0847 
STATUS 
red 
any card 
PLLs are not locked 
Verify that the STATUS LED on the BIC 
CRIC is green 
Check the Alarm Manager for PLL LOCK 
alarm; wait 3 minutes for PLLs to lock; if 
they do not: 
Verify integrity of Ethernet connection 
between BIC and AIC. 
Contact the TAC:  (800) 328-0847