MC-Series High-Power System 
 
Scheduled and Unscheduled Maintenance 
998--01 Rev X1 
RadioFrame Networks, Inc. 
CONFIDENTIAL AND PROPRIETARY 77 
 
 
7.4.2  RBS 
Table 23  RBS LED Indications 
LED 
Indication 
Condition 
Corrective action 
green normal 
condition 
none 
not lit 
no power to RBS 
Verify that RBS circuit breaker on PDU 
is ON. 
Check power connection to PDU. 
Measure power input, and compare 
with tolerances listed in section 
2.5,”Specifications”. 
Verify that the power source is 
operational. 
Contact the TAC:  (800) 328-0847 
STATUS 
red 
timing is not synchronized to 
the group (A, B, or C) 
Board unable to boot 
Power cycle the RBS using the circuit 
breaker on the PDU. 
Contact the TAC:  (800) 328-0847 
green RadioBlade 
transceiver 
present and operational 
none 
RadioBlade transceiver not 
present 
none 
not lit 
RadioBlade transceiver 
present 
Reseat RadioBlade transceiver. 
RADIOBLADE 
TRANSCEIVER 
STATUS 
red 
RadioBlade transceiver is in 
error state 
Reseat RadioBlade transceiver. 
If still red, replace RadioBlade 
transceiver. 
7.4.3  RF Shelf 
Table 24  RF Shelf LED Indications 
LED 
Indication 
Condition 
Corrective action 
green normal 
condition 
none 
POWER 
not lit 
no power to RF shelf 
Verify that RF circuit breaker on PDU is 
ON. 
Check power connection to PDU. 
Measure power input, and compare with 
tolerances listed in section 
2.5,”Specifications”. 
Verify that the power source is operational. 
Contact the TAC:  (800) 328-0847 
green normal 
condition 
none 
not lit 
not receiving power 
Verify power to RF Shelf (see “POWER” 
above). 
ALARM 
red 
alarm condition 
Check the Alarm Manager for: 
RF SHELF MINOR, replace fan. 
RF SHELF MAJOR, replace RF shelf. 
Contact the TAC:  (800) 328-0847