MC-Series System Installation & Testing 
Scheduled and Unscheduled Maintenance 
RadioFrame Networks, Inc.
  
81 
Cause:   
Loss of Signal 
System Reaction: Reset 
RadioBlade 
Additional Info
Radio Blade index 
Repair Action:  This problem is a result of the DSP not receiving packets from the RadioBlade. If 
this alarm does not clear itself or is happening frequently then replace the RadioBlade.  If the 
problem still persists, replace SPAM and/or APC. 
7.4.4.32 
RB VGA Error 
ID
 
  4103 
Service:   iden 
Severity:   minor 
Cause:   
Degraded Signal 
System Reaction: Reset 
RadioBlade 
Additional Info
Radio Blade index 
Repair Action:  This is the result of the system detecting a RadioBlade reporting erroneous vga 
values.  Replace RadioBlade. 
7.4.4.33 Carrier 
Assignment 
failure 
ID
 
  4104 
Service:   iden 
Severity:   major 
Cause:   
Call Establishment Error 
System Reaction: BR 
Disabled 
Additional Info: Carrier 
Frequency 
Repair Action:  This is a result of an unusually high number of assignment failures from a 
particular Mobile on a particular BR. This is an indication of an RF problem with one of the 
RadioBlades.  The debug field is the frequency of the carrier that would not allow assignment too.  
The event log will contain the RadioBlade index of the PCCH. This RadioBlade index will indicate 
the RBS, the frequency will be the carrier in that RBS.  Replace the RadioBlade. 
Note: This alarm does not have a clear 
7.4.4.34 
DSP reset threshold exceeded 
ID
 
  4105 
Service:   iden 
Severity:   critical 
Cause:   
Threshold Crossed 
System Reaction: System 
Reset