MC-Series System Installation & Testing
Scheduled and Unscheduled Maintenance
RadioFrame Networks, Inc.
83
Service: iden
Severity: minor
Cause:
Degraded Signal
System Reaction: Reset
RadioBlade
Additional Info:
Radio Blade Index
Repair Action: This is a result of either an interference source or the RadioBlade is going out of
Calibration. Lock or swap RadioBlades with that carrier. If the problem follows the carrier, most
likely interference. If the problem follows the RadioBlade, most likely out-of-cal RadioBlade is the
source.
Calibration. Lock or swap RadioBlades with that carrier. If the problem follows the carrier, most
likely interference. If the problem follows the RadioBlade, most likely out-of-cal RadioBlade is the
source.
Note: This alarm does not have a clear
7.4.4.39
RB Failed to synchronize
ID:
4112
Service: iden
Severity: minor
Cause:
Timing Problem
System Reaction: SPAM
Reset
Additional Info: None
Repair Action: After 3 attempts to re-synchronize the RadioBlade, this alarm is issued and the
SPAM is reset. If problem persists, replace RadioBlade or replace SPAM.
SPAM is reset. If problem persists, replace RadioBlade or replace SPAM.
Note: This alarm does not have a clear
7.4.4.40
RB Error state
ID:
4113
Service: iden
Severity: major
Cause:
Equipment Malfunction
System Reaction: RadioBlade
Locked
Additional Info:
Radio Blade index
Repair Action: System failed to read EEPROM calibration data from the RadioBlade. Try a
different slot/RFU or replace RadioBlade.
different slot/RFU or replace RadioBlade.
7.4.4.41
Tx DSP not responding
ID:
4115
Service: iden
Severity: major