Opticon Sensors Europe BV H32 User Manual

Page of 29
Opticon 
H - 32  
Specifications Manual 
 
 
 
 
 
19 
 
<Conditions>  
Bar Code Sample  
  
: The above codes specified in Chapter 8 
Distance  
: 100 mm from the front edge of the camera module  
Angle  
: α = 0°, β =+15°, γ = 0°  
Curvature  
: R = ∞  
For the pitch angle and tilt angle measurement, set the skew angle β = +15°  
 
9.3.  Wide Bar Code 
Code 39 with width of 100 mm and resolution of 0.2 mm can be read.  
 
 
Conditions>  
Bar Code Sample  
: 0.20 mm Code 39 specified in 
Chapter 8  
Distance  
: 160 mm from the front edge of the 
camera module  
Angle  
: α = 0°, β =+15°, γ = 0°  
Curvature  
: R = ∞  
 
9.4.  Motion Tolerance 
UPC bar code 100% can be read when it is moving at 2m/s.  
 
<Conditions>  
Ambient Temperature and Humidity 
 
: Room temperature and Room humidity 
Ambient Light  
: 500 lux to 1000 lux (on the surface of a bar code)  
Distance  
: 130 mm from the front edge of the camera module  
Angles  
: α= 0°  
Skew  
: β = 15°  
Tilt  
: γ = 0°  
Curvature  
: R = 
∞  
Power Supply Voltage  
: 3.3 and 5.0 V  
PCS (1D and 2D)  
: 0.9 or higher  
Bar Code Sample  
: UPC with 0.33 mm resolution specified in Chapter 
8  
 
 
                  
 
 
Figure 6: Motion tolerance MDI3100