Opticon Sensors Europe BV H32 Manuel D’Utilisation
Opticon
H - 32
Specifications Manual
19
<Conditions>
Bar Code Sample
Bar Code Sample
: The above codes specified in Chapter 8
Distance
: 100 mm from the front edge of the camera module
Angle
: α = 0°, β =+15°, γ = 0°
Curvature
: R = ∞
For the pitch angle and tilt angle measurement, set the skew angle β = +15°
9.3. Wide Bar Code
Code 39 with width of 100 mm and resolution of 0.2 mm can be read.
Conditions>
Bar Code Sample
Bar Code Sample
: 0.20 mm Code 39 specified in
Chapter 8
Distance
: 160 mm from the front edge of the
camera module
camera module
Angle
: α = 0°, β =+15°, γ = 0°
Curvature
: R = ∞
9.4. Motion Tolerance
UPC bar code 100% can be read when it is moving at 2m/s.
<Conditions>
Ambient Temperature and Humidity
Ambient Temperature and Humidity
: Room temperature and Room humidity
Ambient Light
: 500 lux to 1000 lux (on the surface of a bar code)
Distance
: 130 mm from the front edge of the camera module
Angles
: α= 0°
Skew
: β = 15°
Tilt
: γ = 0°
Curvature
: R =
∞
Power Supply Voltage
: 3.3 and 5.0 V
PCS (1D and 2D)
: 0.9 or higher
Bar Code Sample
: UPC with 0.33 mm resolution specified in Chapter
8
8
Figure 6: Motion tolerance MDI3100