Installation of outer housing
Installation of the outer housing requires two holes for the fastening screws and one hole for the
cable bushing.
Installation of the outer housing requires
three holes with a diameter of 7 mm.
three holes with a diameter of 7 mm.
Since the screw heads on the inside of the door
are covered by the inner housing, the holes for
installation of the outer housing must be drilled
at the height of the mounting holes of the inner
housing. The lateral position of the outer hous-
ing must be in the range of 22-72 mm. (see dia-
gram)
are covered by the inner housing, the holes for
installation of the outer housing must be drilled
at the height of the mounting holes of the inner
housing. The lateral position of the outer hous-
ing must be in the range of 22-72 mm. (see dia-
gram)
The length of the M4 fastening screws must be
selected according to the thickness of the ex-
isting door.
The following standard lengths are available:
Door thickness 10-15 mm
selected according to the thickness of the ex-
isting door.
The following standard lengths are available:
Door thickness 10-15 mm
2 x M4x10
Door thickness 16-21 mm
2 x M4x16
Special lengths:
Door thickness 22-25 mm
2 x M4x20
Door thickness 26-30 mm
2 x M4x25
Note:
Incorrect screw lengths can cause damage of
the outer housing.