Installation of inner housing
Installation of the inner housing requires four fastening screws. The type of fastening screw depends
on the existing door material. As standard, M5x25 screws are used for fastening the inner housing.
Fastening of the inner housing requires four M5 screw threads (threaded sleeves) in the door.
Installation of the inner housing requires
four M5 screw threads.
four M5 screw threads.
After installation of the outer housing, the 6-
pin connecting cable must be pushed through
the opening of the inner housing. The inner
housing is then tightened using four screws.
pin connecting cable must be pushed through
the opening of the inner housing. The inner
housing is then tightened using four screws.
After fastening of the inner housing, the 6-pin
connecting cable must be plugged onto the 6-
pin connector on the board.
Finally, the battery pack is mounted in the
upper part of the inner housing and the 2-pin
battery cable plugged onto the 2-pin connect-
or on the board.
The upper and lower covers can then be at-
tached and fastened with the battery screw
(TX20).
connecting cable must be plugged onto the 6-
pin connector on the board.
Finally, the battery pack is mounted in the
upper part of the inner housing and the 2-pin
battery cable plugged onto the 2-pin connect-
or on the board.
The upper and lower covers can then be at-
tached and fastened with the battery screw
(TX20).