Schulte-Schlagbaum AG SOT01 User Manual

Page of 12
SAG
SAFE-O-TRONIC
Installation
Schulte-Schlagbaum AG
Page 8 of 12
SOT-Manual.DOC
5.2. Configuring the SAFE-O-TRONIC with the "SetupKey"
The SetupKey is used to configure the System-ID, the cabinet number, the operating mode and
the group number in the SAFE-O-TRONIC . Only than can the SAFE-O-TRONIC be used in the
system.
An already configured SAFE-O-TRONIC will no longer accept the SetupKey. To change the con-
figuration of a SAFE-O-TRONIC , the latter must first have been cleared using a valid ResetKey.
CAUTION:
Use only a SetupKey having the correct Group No. and System-ID.
Sequence:
1. Set the parameters on megalock Admin or on the megalock Programmer and program them
into the SetupKey.
Set the following data:
- Next SAFE-O-TRONIC number to be programmed (cabinet number)
- Operating mode (free cabinet select / fixed cabinet assignment / multi-user mode)
- Group No. to which the SAFE-O-TRONIC is to be assigned.
2. Go to the first SAFE-O-TRONIC with the SetupKey, waken up the lock and configure it by pre-
senting the SetupKey.
The SetupKey must be held in front of the rotary knob until the SAFE-O-TRONIC ac-
knowledges this by causing the green LED to flash
.
3. Now the next SAFE-O-TRONIC can be configured with a sequential cabinet number.
Assigning the megalock number is done according to the same principle.
Once the SAFE-O-TRONIC
has uploaded
the number, it increments the number on the
SetupKey by +1.
Now the number for the next SAFE-O-
TRONIC 
is stored on the SetupKey, and as
many megalocks as desired can be initialized
with a sequential number without having to
first reprogram the SetupKey.
NOTE:
If a gap in the sequential numbering of the
SAFE-O-TRONIC s is desired, such as at
the end of a row of cabinets, the new
cabinet number will have to be pro-
grammed into the SetupKey.