Installation
Schulte-Schlagbaum AG
Page 9 of 12
SOT-Manual.DOC
5.3. Resetting a SAFE-O-TRONIC with the "ResetKey"
Clearing a SAFE-O-TRONIC may be necessary for example if a mistake was made in initializing
(e.g. wrong cabinet number) or if a SAFE-O-TRONIC needs to have a different configuration.
NOTE
The ResetKey is only accepted by the SAFE-O-TRONIC if it is unlocked!
The megalock is reset in the following way:
1. Activate megalock (push rotary knob)
2. You have 8 seconds to hold the ResetKey in front of the rotary knob in the sensing zone
of the SAFE-O-TRONIC antenna.
Once the parameters in the SAFE-O-TRONIC have been cleared, the SAFE-O-TRONIC
acknowledges the process by causing the green LED to come on for a brief time followed
by simultaneous flashing of the green and red LED.
3. Now the SAFE-O-TRONIC can be reconfigured with a SetupKey
(see: 5.2. Configuring the SAFE-O-TRONIC with the "SetupKey").
5.4. Replacing a SAFE-O-TRONIC
If it becomes necessary to replace a SAFE-O-TRONIC , the new SAFE-O-TRONIC must first:
1. be configured with the megalock number and other parameters using the SetupKey
(see: 5.2. Configuring the SAFE-O-TRONIC with the "SetupKey") and
2. be actuated with a MasterKey to ensure that the new SAFE-O-TRONIC accepts only
MasterKeys having the currently valid MasterKey-Generation.