ANHANG C: LED Blink-Codes
LED Signal
Description
¥  
1 x green
(3 Sec)
 
Reset-Indicator (e.g. first activation after battery replacement)
¥  
1 x green
 
OK (Action was successfully completed)
¥ 
1 x red
 
Unknown megaKey Type
 
Action is only allowed on unlocked SAFE-O-TRONIC e.g. ResetKey or
SetupKey.
 
The present free-megaKey has locked another SAFE-O-TRONIC.
 
fixed-megaKey, multi-megaKey or ProgKey is not assigned to this SAFE-
O-TRONIC
¥ 
2 x red
 
SAFE-O-TRONIC is in new or in reset state (e.g. after using ResetKey)
 
TestKey or SetupKey was used at an initialised SAFE-O-TRONIC
¥
 3 x red
 
megaKey is admitted at another SAFE-O-TRONIC System.
 
megaKey or MasterKey are assigned to another group
¥
 4 x red
 
Time limit or valid period exceeded
 
The megaKey is in moment not admitted at this SAFE-O-TRONIC
¥
 5 x red
 
The Key-Generation stored on the MasterKey or multi-megaKey or Sys-
temKey is no longer valid for this SAFE-O-TRONIC.
¥
 6 x red
 
Handling error: SAFE-O-TRONIC was not locked after a actuation with a
valid megaKey
 
Mismatched type of megaKey and megalock operating mode (e.g. free-
megaKey at SAFE-O-TRONIC in fixed cabinet assignment or fixed-
megaKey at SAFE-O-TRONIC in free cabinet selection, etc. ...).
 
ProgKey at a SAFE-O-TRONIC which doesn't work in Matrix-Mode.
 
ClockSetKey or DSTKey at SAFE-O-TRONIC with disabled real time
clock.
 
Data on megaKey are incorrect or corrupt (e.g. megaKey was to short in
detection range of the SAFE-O-TRONIC)
¥
 ... 
¥
3 x red .. green ....
 
Battery alarm
Before SAFE-O-TRONIC could used again the battery must be replaced.
¥ 
¥
3 x red & green
 
SAFE-O-TRONIC is blocked after MasterKey I was used. Use MasterKey
II to unblock SAFE-O-TRONIC for further activation's
l
constant
red&green
 
Internal Failure