Radwin Ltd. 5XACMD3CN User Manual

Page of 112
FinM Deployment Guide
Release 4.2.46
3‐27
Configuring Transportation Mobile Units (TMUs)
Configuring the Radio Network
Figure 3‐16: TBS ‐ Re‐configuration
3. Click OK. The Configurator will take all parameters as shown in the Configurator that 
are relevant for a TBS and carry out the action as determined by the Download 
software
 option you have selected (see 
Download software:
 on page
3‐4
). If the 
action includes downloading to a unit, it will download to the unit whose IP address 
appears in the First Installation window, regardless of which unit appears in the 
Base Name window.
It may take about a minute to complete. You will receive one of the completion mes‐
sages described in 
 below.
3.6.2 Configuring Transportation Mobile Units (TMUs)
Use this procedure to carry out changes in the configuration parameters of the TMUs. This 
includes changing or setting its IP address. 
1.  For a first‐time configuration, connect the TMU’s PoE socket to a PoE device (see 
 for connection instructions), and in turn, connect the PoE device to 
your laptop or a LAN connection. 
For a re‐configuration of a TMU already installed in the field, you can rely on your 
network’s connection. 
2. Open the Configurator.
3. From the Main tab, click the Line pull‐down menu and select the line on which the 
TMU is defined (see 
). 
4. From the Download Software pull‐down menu, select the appropriate 
configuration option (see 
page 3‐4
 for a description of these options). 
Since TMUs are usually mobile, make sure these devices will be in continuous 
contact during the configuration process. Our recommended “best practice” is to 
find an opportunity when the TMU to be configured is immobile.