Chapter 5 Diagnostics and Troubleshooting
AirMux-104 Installation and Operation Manual
5-2 Error
Detection
Table 5-1. AirMux-104 Alarms and Information Messages (Cont.)
Message Description
E1 Interface – LOF
Loss of Frame alignment is reported by E1 interface
E1 Interface – AIS
Alarm Indication Signal is reported by E1 interface
E1 Interface – RAI
Remote Alarm Indication is reported by E1 interface
E1 Interface – CRC
CRC error was detected at E1 interface
E1 Interface – CRC_E_BIT
CRC E-Bit error was detected at E1 interface
E1 Interface – Loopback
A loopback is active on E1 interface
Failed to download data to the
remote RT
AirMux-104 failed to download configuration data to the remote RT
Failed to download data to the local
RT
AirMux-104 failed to download configuration data to the local RT
Link Resetting
Wireless link was reset from the management station. This alarm is
usually caused by automatic reset after link configuration.
usually caused by automatic reset after link configuration.
Local RT Resetting
The local RT was reset from the management station.
Error loading trap catcher
AirMux Manager detected that the SNMP port 162 of the
management station has been already captured by another
application and cannot receive traps.
application and cannot receive traps.
Figure 5-1. AirMux-104 Alarms and Status Indications
Alarm
Logger
E1 Status
(Local Unit)
Radio Link
Status
Loopback
Status
(Local Unit)
Loopback
Status
(Remote Unit)
(Remote Unit)
E1 Status
(Remote Unit)
Ethernet
Status
Status
(Local Unit)
Ethernet
Status
(Remote Unit)
(Remote Unit)
Radio Status
(Local Unit)
Radio Status
(Remote Unit)