Norsat International Inc. NSLK3200 User Manual

Page of 108
Page 56
 
Norsat NewsLink
                                             
           099-20003-01OM 
                                                                    
Norsat
reading of 90 for the signal strength meter is typical. The default
value is the alignment carrier that is set up in your satellite profile.
C
ARRIER
 S
IGNAL
 S
TRENGTH
: indicates the signal strength for the car-
rier; value in the range 0 - 999. A digital display located on the
junction box also displays the carrier signal strength; refer to
Figure 48 on page 56.
FIGURE 48.
Signal Strength Indicator.
Spectrum Analyzer
To verify that the antenna is pointed at the correct satellite, check the spectral
signature on the Spectrum Analyzer and compare it with the known signature.
Alternatively, if a beacon frequency is known, find the beacon on the Spec-
trum Analyzer.
17. To launch the Spectrum Analyzer, click on the 
S
PECTRUM
 A
NALYZER
 button.
The spectrum for the receiver is displayed in the 
R
ECEIVER
 panel, with fre-
quency [MHz] on the horizontal axis and decibels on the vertical axis;
refer to Figure 49 on page 57.
N
OTE
The 
C
ARRIER
 S
IGNAL
 S
TRENGTH
 meter will be disabled.