Riello Sentinel Dual 10000VA CSDLK10TA5 User Manual

Product codes
CSDLK10TA5
Page of 5
www.riello-ups.co.uk
UP
S
49
• Operation guaranteed up to 40°C (the 
components are designed for high 
temperatures and are thus subject to 
less stress at normal temperatures)
• Two built-in IEC output sockets with 
thermal protection (5-6- 8-10 kVA)
• Two 10A outpit sockets with Power 
Share on the 5-6-8-10 kVA models 
that can be turned off when the mains 
power supply fails.
Operation selection
Programmed using the software supplied or 
manually via the front mimic panel
• On-line double conversion Mode: to 
provide maximum protection.
• ECO Mode:to increase output (up to 
98%), operating in line interactive (VI) 
mode, powering loads from the mains. 
• Smart Active Mode: the UPS 
automatically decides upon the 
operating mode (VI or VFI) based on the 
quality of the mains power supply.
• Emergency Mode: the UPS can be 
selected to function only when mains 
power fails (emergency mode only)
• Frequency converter (50 or 60 Hz).
High quality output voltage
• Even with non-linear loads (loads with a 
rest factor of up to 3:1)
• High short circuit current on Bypass
• High overload capacity 150% by 
inverter (even with mains failure
• Filtered, stabilised and reliable voltage 
(double conversion On-line technology 
(VFI compliant with IEC 62040-3) 
with filters for the suppression of 
atmospheric disturbances.
• Power factor correction: UPS input 
power factor, close to 1 and sinewave 
current absorption
High battery reliability
• Automatic and manual battery test
• Reduced ripple component (detrimental 
to the batteries) using the “LRCD”  (Low 
Ripple Current Discharge) system
• Batteries are user replaceable without 
interruption to the load  (Hot Swap)
• Unlimited extendible runtime using 
matching Battery Boxes
• High hold-up time and wide input 
voltage range. The batteries are not 
used during mains power supply 
failures of <40 ms or within an input 
voltage range of 84-276V.
Emergency Back-up function
This configuration is designed for 
emergency systems incljuding lighting, 
fire detection/exit systems and alarms. 
When the mains power supply fails, the 
inverter begins powering the loads with 
a progressive start (Soft Start) in order to 
prevent overload. 
Battery optimisation
The wide input voltage range and a high 
hold-up time minimise battery usage and 
increase efficiency and battery life; for 
smaller power breaks, energy is drawn from 
a group of appropriately-sized capacitors.
Power Share (5-10kVA)
Two configurable IEC output sockets, 
for runtime optimisation, with the facility 
to programme the sockets to switch-off 
low priority loads on mains power failure; 
alternatively, emergency loads, normally 
not powered when the mains is present, 
can be activated.
Low noise output
Using digital PWM control, the speed 
of the load dependent fans is adjusted 
depending on the temperature of the two 
internal heatsinks, to achieve a reduced 
noise level of 45dB and help extend their 
operating life.
Other features
• Output voltage can be selected using 
software (220-230-240V)
• Auto-restart when mains power is 
restored (programmable via software)
• Bypass on: when the machine is 
switched off, it automatically goes into 
bypass and battery charge mode
• Minimum load switch-off
• Low battery warning
• Start-up delay
• Total microprocessor control
• Automatic bypass without interruption
• Use of IMS modules (Insulated Metallic 
Substrates)
• Statuses, measurements and alarms 
available on standard, backlit display.
• UPS digital updating (flash upgradable)
• Input protection through resettable 
thermal switch 
• Standard Back-feed protection: to 
prevent energy from being fed back to 
the network
• Manual switching to bypass.
90°
90°
2. Rotate the mimic panel counter 
clockwise and then secure it back 
in place
1. Release the mimic panel by 
applying pressure to the catch
3. Rotate the UPS 90°
4. Attach the rack supports