Tagsys S.A. LSP3CLEAR-L40 User Manual

Page of 68
 
22/68 
Revision 2.1 
December 2009 
 
Figure 4: Clearance Distances around Pedestals 
 
A
:  Indicates  the  distance  (6  ft. 
6in.)  to  a  permanent  librarian 
position. 
B
:  Indicates  the  distance  (8  ft.) 
from other RFID stations. 
C
:  Indicates  the  recommended 
distance   (36 in. face panel to 
face 
panel) 
between 
pedestals. 
D
:  Indicates 
the 
minimum 
distance  (31½  in.)  between  a 
pedestal  and  large  metal 
object. 
E
:  Indicates 
the 
minimum 
distance  (20  in.)  between  a 
pedestal  and  small  metal 
object. 
F
:  Indicates 
the 
minimum 
distance  (30  ft.)  between 
Master 
pedestals 
(specific 
synchronization 
ID, 
see 
section  5.2  “Understanding 
the  L-SP3  Synchronization 
Process”). 
4.3.3  Installing the Pedestal 
Once  the  L-SP3  will  be  powered,  the  photoelectric  sensors  will  emit  a  red  light  beam. To 
precisely  align  the  sensors  and  the  reflector,  an  orange  LED  is  present  on  the  back  of  the 
photoelectric  sensor.  When  the  orange  LED  is  continuously  on,  the  sensor  and  the  reflector  are 
perfectly aligned. 
To see these LED, one must first unscrew the Plastic Bottom Cover covering the dual cells 
(see picture of 
5.5.1 Resetting the Counter Display
). 
On the contrary when the orange LED is blinking or off, then you have to adjust the photoelectric 
sensor,  so  that  the  red  light  beam  is  centered  with  the  opposite  reflector.  This  operation  is 
achieved using a white paper to clearly see where the red light beam is pointed at. When perfectly 
centered, the orange LED will continuously be ON. 
On figure  7  below,  the  two  Beam  Crossing  Cells  support  is  shown.  To do  a fine  adjustment  of 2 
beams, use a hexagonal key to screw or unscrew the top left screw (to adjust height of beams) and 
the bottom right screw (to adjust the lateral positioning of the beams). They are spring loaded to 
improve accuracy and keep in place the two sensors after adjustment. 
 
CAUTION: Each L-SP3 should be installed within following tolerances: 
Horizontal angular alignment tolerance with reference to pedestals 
alignment: 0° +/-2° 
Vertical angular tolerance with reference to ground surface : 90° +/-1°  
 
CAUTION: Each L-SP3 must be installed at least 2 meters away from 
sliding doors. Metal frames do pick up & radiate stray Radio ham 
electromagnetic field which can lead to false triggering.  Prior to 
installation a site survey is highly recommended. 
36 in. 
(91.4 cm) 
 
 6 ft. 6 in. (2 m) 
 
  
30 ft. (9.1 m) 
 
8 ft. (2.4 m) 
 
 
 
31½ in. (80 cm) 
 
 