4.2  L-SP3 RFID System Components 
The components included in the L-SP3 RFID System package are listed in 
Table 1
 
 
Table 1: L-SP3 System Components 
Quantity 
Description 
L-SP3 Pedestal 
40 mm Philips-head, countersunk screws with a diameter of 6 mm  
2 ways 3.81mm Green Screw Tightening Plugs Vertical Cable Entry for 
Synchronization Cable 
4 ways 3.81mm Green Push-On Plugs Vertical Cable Entry for I/O Wiring 
4.3  L-SP3 Pedestal 
4.3.1  Tools Required 
The following tools are required during installation:  
  Measuring Tape  
  Square 
  Hand Drilling Machine with 4 mm, 8-mm and 19-mm drilling bits 
  Philips-head screwdriver 
  Spirit Level 
4.3.2  Placement of Pedestals 
Pedestals  must  be  mounted  between  800mm  and  980  mm  apart  (edge  to  edge)  for 
maximum  reliable  performance.  There  should  be  at  least  one  pair  of  pedestals  at  each 
entrance/exit point of the library. There should be a pedestal at each edge of the entrance, and a 
clear space of at least 500 mm around the edge of the pedestals to ensure that the antennas will 
not  be  detuned.  This  clear  space  must  not  contain  any  metallic  objects,  but  may  contain  some 
substrates  such  as  non-metallic/non-conductive  building  materials  such  as  wood,  glass, 
chipboards and plasterboards. 
 
Be cautious to properly align the pedestal in order to centre the photoelectric beam sensor on the 
reflector of the next pedestal. 
 
 
CAUTION: This equipment is intended for indoor use only under the 
conditions described in this document. Should it be used outside these 
conditions cannot be guaranteed, and is not recommended. Please read 
section 
1
 “
Publishing Information
” before installation or use.
 
 
CAUTION: In case several Pedestal rows (group of Pedestals) to be 
installed it is mandatory every L-SP3 being positioned in the same 
direction (all people counter of each looking toward the same direction).  
This would prepare the installation for future implementation of direction 
sensing.