5.1.3  EAS Mode versus AFI Mode 
EAS mode is only supported by the C370 or C370-L (NXP chip). AFI mode is supported by most 
ISO15693  chips,  from  major  chip  manufacturers  (NXP,  Texas  Instrument,  STM,  Infineon, 
MeMarin…). 
EAS digital burst is a prime number data stream of 128 bits which is read out after sending a check 
EAS command to the Tag. This dedicated EAS command in only implemented in NXP SLI chips. 
C220  &  C320  TAGSYS  chips  EAS  signal  is  respectively  100kHz  free  running  and  106kHz 
synchronous  burst  sent  by  the  chip  at  power  on  reset  during  a  few  ms  when  RF  field  is  first 
established  and  when  EAS  bit  is  set.  This  mode  is  only  supported  by  TAGSYS  which  owns  the 
chip  design.  C220  supports  only  EAS  detection,  no  memory  content  read  out  is  possible.    C320 
supports both EAS detection and 256 bits memory content read out for data model support. 
The  AFI  (Application  Family  Identifier)  is  an  8bit-field  defined  in  the  ISO15693  standard  but  not 
mandatory. Whenever issuing an inventory command with a specific AFI code, only Labels with the 
same matching AFI code will reply with its UID. Generally the code 9E is used to say that the book 
has not been properly checked out, thus will be detected by the pedestals. 
5.2  Understanding the L-SP3 Synchronization Process  
5.2.1  Standard Synchronization Mode 
To manage a group of pedestals, a synchronization burst is sent by the master pedestal to all 
the slaves’ pedestals, a token being propagated back and forth as in a token ring process. This is 
called the synchronization process. 
  Only one pedestal is defined to be the master who emits a synchronization burst to the next 
slave in close proximity who in turns emits it to the next slave and so forth. 
  The  other  pedestals,  configured  as  slaves,  get  the  synchronization  from  the  neighboring 
pedestal and emits back to the next Slave of higher index. 
 
 
Figure 12: Chronogram Sample (1 Master/ 4 Slaves) 
 
 
 
 
 
 
Default Configuration of the L-SP3 is set to Master 2 Pedestals. 
Pt 
Synchronization Burst 
MASTER 
 
 
SLAVE1 
 
SLAVE2 
 
SLAVE 3 
 
SLAVE 4 
T_scan