Tagsys S.A. LSP3CLEAR-L40 User Manual

Page of 68
 
December 2009 
Revision 2.1 
31/68 
 
5.2.2  Wireless Synchronization 
 
 
 
When more than two pedestals are installed, it is mandatory to install the Master on the far left or 
right of the slave’s line for a better propagation and detection of the air synchronization burst. 
Figure  13
  below
 
shows  an  example  of  optimal  configuration.  Slaves  must  be  placed  with  the 
correct  index  corresponding  to  its  physical  location  in  order  to  carry  other  the  token  allowing 
starting to scan its 3 own antennas before handing over the token to the next neighboring pedestal. 
 
Figure 13: 3 Pedestals Configuration Example and Token Propagation 
 
Red Arrow: Wireless Synchronization Token hand over
 
Blue arrows: Wire Synchronization Token hand over 
5.2.3  Synchronization by a pair of Wires 
This mode is mandatory in noisy environments or when nearby RFID devices are placed too 
near within a couple of meters from any pedestals preventing the installation using wireless 
settings. 
It is also mandatory when using too many pedestals (typically above 4 to 6 pedestals) as 
wireless burst signal needs to go to the last slave N pedestal and then back going through all N 
slaves before the master can scan its detection volume again. Processing time is thus equal to 2N 
times Pt in wireless mode.  
Using a synchronization cable, the token can be directly handed over by the last slave N to 
the Master without having to go through all N Slaves pedestals again. Overall scanning time is thus 
equal to N times Pt, half of the wireless time. 
In  this  case  the  L-SP3  configuration  settings  have  to  be  changed  from  “Wireless”  to 
“Hardwire”  Synchronization  in  the  L-SP3  Configuration  Tool  program,  “Advanced  Configuration” 
last tab. See Figure 12 to see the correct fields to be modified. There will always be one & only one 
 
In Standard Synchronization mode, section 5.2.1, if pedestals spacing 
exceeds the recommendation of section 4.3.2 “Placement of Pedestals”, 
wire synchronization becomes mandatory.