7 Maintenance 
7.1  Servicing the Pedestals 
No  regular  servicing  or  maintenance  is  required,  except  for  keeping  the  covers  clean,  and 
occasionally checking the integrity of the cover seals.  
It  is  recommended  that  the  pedestal  unit  be  inspected  at  least  once  per  year  by  an  approved 
TAGSYS technical representative. 
Refer to section 1.2 “Care and Maintenance” for general maintenance information. 
7.2  Servicing the Electronics Unit 
- Fuse characteristics: 
  F1 on AC mains: Schurter FST, 5X20mm, Time-Lag T, H, 250VAC, 500mA 
  F2 on DC supply: Schurter SPT,  5X20mm, Time-Lag T, H,  250VAC/300VDC, 2A  
- How to change them: 
Fuses are located behind the plastic cover located at the bottom of the L-SP3 pedestal. 
1.  Unscrew the 4 screws holding the plastic cover on sensors and counter display side. 
2.  Unscrew the fingertip head fuse and replace the tripped fuse with the specified replacement 
one. Only use the specified UR listed 5x20mm fuses from Schurter for replacement (please 
see figure below). 
 
Figure 33: Mains Fuses Location and Ratings 
 
24V DC Secondary Fuse F2: 2A 300V DC 
IEC Mains Voltage Outlet 
Mains Fuse F1: 0A5 250V AC 
IEC Mains Voltage Inlet