7 Maintenance
7.1 Servicing the Pedestals
No regular servicing or maintenance is required, except for keeping the covers clean, and
occasionally checking the integrity of the cover seals.
It is recommended that the pedestal unit be inspected at least once per year by an approved
TAGSYS technical representative.
TAGSYS technical representative.
Refer to section 1.2 “Care and Maintenance” for general maintenance information.
7.2 Servicing the Electronics Unit
- Fuse characteristics:
F1 on AC mains: Schurter FST, 5X20mm, Time-Lag T, H, 250VAC, 500mA
F2 on DC supply: Schurter SPT, 5X20mm, Time-Lag T, H, 250VAC/300VDC, 2A
- How to change them:
Fuses are located behind the plastic cover located at the bottom of the L-SP3 pedestal.
1. Unscrew the 4 screws holding the plastic cover on sensors and counter display side.
2. Unscrew the fingertip head fuse and replace the tripped fuse with the specified replacement
one. Only use the specified UR listed 5x20mm fuses from Schurter for replacement (please
see figure below).
see figure below).
Figure 33: Mains Fuses Location and Ratings
24V DC Secondary Fuse F2: 2A 300V DC
IEC Mains Voltage Outlet
Mains Fuse F1: 0A5 250V AC
IEC Mains Voltage Inlet