If wireless synchronization is selected: 
• 
Select the antenna that should be used for emitting and receiving synchronization bursts.  
• 
Select the synchronization burst detection sensitivity. If default value does not ensure the 
correct synchronization of all slaves then it is possible to adjust the sensitivity of the non-
synchronized slaves. You just have to adjust the detection level until you get the required 
synchronization (LEDs flickering cyclically). Sensitivity can be adjusted between 50 (high 
sensitivity) and 2000 (low sensitivity). 
 
 
Figure 27: Master/Slaves Synchronization Antenna Best Configuration 
 
 
 
 
 
 
 
 
 
 
 
 
 
Configuring advanced alarm detection parameters 
In “Alarm Detection Options” section: 
• 
Select alarm detection sensitivity. Decrease sensitivity in case too many false alarms occur. 
• 
Select up to four different AFI values as two hexadecimal digits. Items whose AFI matches 
one of those values will trigger an alarm. 
Configuring advanced alarm signaling parameters 
In “Alarms” section: 
• 
Select the alarm report interval. If the same stolen item passes through the gate several 
times, it will be reported only once every n seconds. 
• 
Select whether or not the alarm should be triggered only if reading of UID/Memory of stolen 
items was successful.  
Configuring antenna sequence, RF output power and region of operation 
 
A  Value  of  1500  &  above  is  recommended  for  first  installation  to  avoid 
synchronization  being  blinded  by  nearby  operating  equipment  and 
noise. 
 
Best  Air  Synchronization  Results  are  obtained  when  using  the  same 
antenna  for  all  Receiving  and  Transmitting  antennas:  all  Top  or  all 
Bottom ones.  