Tagsys S.A. LSP3STANDARD User Manual

Page of 63
 
Library Security Pedestal 3 
 
50/63 
Revision 0.2 
May 2009 
In “Antennas and Power” section: 
• 
Select the RF output power. The output power can be lowered to avoid disturbing nearby 
RFID systems (in such a case, check system performance). The output power can be 
increased, but only to carry on tests. 
• 
Select antenna sequence used when scanning the pedestal. Select “Top>Center>Bottom” 
for standard operation or specifically an antenna for diagnosis operations (Top, Center or 
Bottom). 
In “Region” section, select the EMC regulations applicable to your region (FCC or ETSI). 
5.5  People Counter & Buzzer Sound Management 
5.5.1  Resetting the Counter Display 
Figure 28: People Counter & Detection Cells Location 
To reset the LCD display use a pointed element (for example: a paper clip). Insert it in the hole on 
the right of the display window and press (not too hard) until you get zero displayed. This will also 
reset the battery backed-up counter. 
 
In  any  case,  for  operational  configuration  output  power  should  not 
exceed 4W to remain compliant with Radio Regulations. 
Buzzer Level Adjust 
LCD Counter Display 
Counter Reset Button